Type a 13-digit NSN, a 9-digit NIIN, a manufacturer part number, or a category name such as “gasket”.

Jump to

FSC 5915 × FILTER,RADIO FREQUENCY INTERFERE

FILTER,RADIO FREQUENCY INTERFERE

5915-01-005-9637 FSC 5915

NSN 5915-01-005-9637 (also written 5915010059637; NIIN 01-005-9637) is a filter, radio frequency interfere in Federal Supply Class 5915, Filters and Networks. 5 manufacturer part numbers from 5 suppliers are on record. It was last purchased in Sep 2026.

Open for bid

No open solicitations on record for this NSN right now.

Search open RFQs on DIBBS →

Can you win it?

This item is coded as suitable for competitive acquisition (AMC 1).

Acquisition method (AMC)
1
Suffix (AMSC)
G
Competition
Coded for competition

AMC 1: suitable for competitive acquisition, second or later time. AMSC G: the government has a complete data package and the rights to use it. The codes describe the item's status on record, not any one solicitation. What the codes mean

What it is — can you make it?

Dimensions, the FLIS specification requirements, and the manufacturer part numbers already qualified against this NSN.

Specifications

From the federal catalog (DLA FLIS / PUB LOG) — what your part has to meet. Cited specification documents can be looked up in ASSIST Quick Search ↗, DoD's public spec repository — copy the document number in.

Requirement Value
OVERALL LENGTH ABHP INCHES NOMINAL 0.970
OVERALL HEIGHT ABKW INCHES MAXIMUM 1.328
OVERALL WIDTH ABMK INCHES MAXIMUM 1.328
UNTHREADED MOUNTING HOLE DIAMETER AEBV INCHES MINIMUM 0.132 AND INCHES MAXIMUM 0.140
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH AEBY INCHES NOMINAL 1.062
VIBRATION RESISTANCE RANGE IN HERTZ AECR 10.0 TO 500.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH AEHA INCHES NOMINAL 1.062
OPERATING TEMP RANGE AFGA CELSIUS -55.0 TO 125.0
SOURCE IMPEDANCE RATING PER FUNCTION AHAQ FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTION AHAQ FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTION AHAQ SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTION AHAQ THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTION AHAQ SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
SOURCE IMPEDANCE RATING PER FUNCTION AHAQ FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTION AHAS SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTION AHAS THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTION AHAS FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTION AHAS SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTION AHAS FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
LOAD IMPEDANCE PER FUNCTION AHAS FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ AHBB FIFTH FUNCTION 5TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ AHBB FOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ AHBB SIXTH FUNCTION 6TH RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ AHBB FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ AHBB THIRD FUNCTION 3RD RADIO INTERFERENCE 400.0
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ AHBB SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0
OPERATING CURRENT RATING PER FUNCTION IN AMPS AHBC FIRST FUNCTION 1ST RADIO INTERFERENCE 7.5
OPERATING CURRENT RATING PER FUNCTION IN AMPS AHBC FOURTH FUNCTION 4TH RADIO INTERFERENCE 7.5
OPERATING CURRENT RATING PER FUNCTION IN AMPS AHBC FIFTH FUNCTION 5TH RADIO INTERFERENCE 7.5
OPERATING CURRENT RATING PER FUNCTION IN AMPS AHBC SECOND FUNCTION 2ND RADIO INTERFERENCE 7.5
OPERATING CURRENT RATING PER FUNCTION IN AMPS AHBC THIRD FUNCTION 3RD RADIO INTERFERENCE 7.5
OPERATING CURRENT RATING PER FUNCTION IN AMPS AHBC SIXTH FUNCTION 6TH RADIO INTERFERENCE 7.5
MAXIMUM VOLTAGE DROP PER FUNCTION AHBE THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.2 AND VOLTS DC 3RD RADIO INTERFERENCE 2.0
MAXIMUM VOLTAGE DROP PER FUNCTION AHBE FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.2 AND VOLTS DC 1ST RADIO INTERFERENCE 2.0
MAXIMUM VOLTAGE DROP PER FUNCTION AHBE FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 1.2 AND VOLTS DC 4TH RADIO INTERFERENCE 2.0
MAXIMUM VOLTAGE DROP PER FUNCTION AHBE SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 1.2 AND VOLTS DC 6TH RADIO INTERFERENCE 2.0
MAXIMUM VOLTAGE DROP PER FUNCTION AHBE SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.2 AND VOLTS DC 2ND RADIO INTERFERENCE 2.0
MAXIMUM VOLTAGE DROP PER FUNCTION AHBE FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 1.2 AND VOLTS DC 5TH RADIO INTERFERENCE 2.0
PRINCIPAL CIRCUITRY TYPE PER FUNCTION AHBL FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTION AHBL SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTION AHBL THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTION AHBL FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTION AHBL FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
PRINCIPAL CIRCUITRY TYPE PER FUNCTION AHBL SIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
INPUT TERMINAL MANUFACTURER CODE AHBN 71468
INPUT TERMINAL IDENTIFICATION AHBP MIL-C-38999 MIL-C-38999
OUTPUT TERMINAL MANUFACTURER CODE AHBS 71468
OUTPUT TERMINAL IDENTIFICATION AHBT MIL-C-38999 MIL-C-38999
MAXIMUM TEMP RISE AHCG CELSIUS 25.0
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ AHCJ 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS AHCK 8.0 AND 10.0 AND 30.0 AND 45.0 AND 60.0
INCLOSURE TYPE AKNA HERMETICALLY SEALED
MOUNTING FACILITY TYPE AND QUANTITY AXHR LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4
FEATURES PROVIDED CBBL MOISTURE RESISTANT AND SHOCK RESISTANT
FUNCTIONAL TERMINAL TYPE AND QUANTITY CQDW LOCATION NOT OTHERWISE SPECIFIED FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT 32
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION CQGC FIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 120.0 AND VOLTS DC 5TH RADIO INTERFERENCE 200.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION CQGC FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 120.0 AND VOLTS DC 1ST RADIO INTERFERENCE 200.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION CQGC FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 120.0 AND VOLTS DC 4TH RADIO INTERFERENCE 200.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION CQGC SIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 120.0 AND VOLTS DC 6TH RADIO INTERFERENCE 200.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION CQGC SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 120.0 AND VOLTS DC 2ND RADIO INTERFERENCE 200.0
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION CQGC THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 120.0 AND VOLTS DC 3RD RADIO INTERFERENCE 200.0
BODY MATERIAL CQRG ALUMINUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE CRDC KILOVOLTS AT SEA LEVEL 1.5
BODY SURFACE TREATMENT CRST CADMIUM
SPECIAL FEATURES FEAT THIRTY-TWO FILTERED FUNCTIONS
PRECIOUS MATERIAL AND LOCATION PMLC GOLD CONTACT SURFACES AND SILVER CONTACT GROUNDING SRING
PRECIOUS MATERIAL PRMT GOLD AND SILVER
STYLE DESIGNATOR STYL —

Manufacturer part numbers

Commercial part numbers cross-referenced to this NSN in the federal catalog — the parts that have been accepted as satisfying this stock number, and who makes them.

Part number CAGE Manufacturer
21-900272-005 77820 AMPHENOL CORP DIV AMPHENOL AEROSPACE OPERATIONS
325075-6 37695 RAYTHEON COMPANY
GC178-2F 25330 COOPER CROUSE-HINDS, LLC DBA GENERAL CONNECTOR
GC178-2F 99447 COOPER INTERCONNECT, INC. DBA COOPER INTERCONNECT
TKJ110798-34 71468 ITT CANNON LLC

What it pays — so you can quote

The government's own price and demand record for this NSN — what past awards cleared at, so you know where to land your quote.

Latest unit price
—
Purchases
0
Total spend
—
Sep 8, 2026
Last purchased
1 · 1.0/yr
Purchase records
$15,568
Total demand
$15,568
Latest award total

Compare with other items

Purchase history

No priced purchases on record for this NSN yet.

Related contract actions

Contract action totals, not unit prices — obligation amounts from USAspending for related awards, shown for context only. These do not appear on the price chart above.

Action date Award # Recipient Agency Obligation
Sep 8, 2026 SPE7M126P7137 ↗ REV-CAP COMPANY, INC. — $15,568

Demand history

Who wins this item

Does one supplier win this every time, and are the winners on the listed-source list? One dot per award.

  • Award in the last 2 years
  • Older award
REV-CAP COMPANY, INC.
last award Sep 2026
Not listed
AMPHENOL CORP DIV AMPHENOL AEROSPACE OPERATIONS
no award yet
Listed source
COOPER CROUSE-HINDS, LLC DBA GENERAL CONNECTOR
no award yet
Listed source
COOPER INTERCONNECT, INC. DBA COOPER INTERCONNECT
no award yet
Listed source
ITT CANNON LLC
no award yet
Listed source
RAYTHEON COMPANY
no award yet
Listed source

REV-CAP COMPANY, INC. won the only award on record. REV-CAP COMPANY, INC. won without being a listed source.

Open RFQs on DIBBS → DIBBS award history ↗

About this data

  • Unit prices: DLA DIBBS award records — every row links to its government record.
  • AMSC: latest observed value from DIBBS solicitation history as of Oct 27, 2026.
  • Contract action totals: USAspending, context only.
  • Data last refreshed: 2026-10-24.
  • Full methodology →
Cite this page
Citation

NSN Explorer. "FILTER,RADIO FREQUENCY INTERFERE." nsnexplorer.com, https://nsnexplorer.com/nsn/5915-01-005-9637/. Data as of November 7, 2026.

Link

https://nsnexplorer.com/nsn/5915-01-005-9637/